Find Medical Cotton Swab Machine, Low-priced Medical Cotton Swab Stick, Disused Medical Cotton Swabs on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
High output full set cotton swab machine
Home > Products > Alcohol swabs packaging machine > High output full set cotton swab machine

High output full set cotton swab machine


  • High output full set cotton swab machine
  • High output full set cotton swab machine
  • High output full set cotton swab machine
  • High output full set cotton swab machine

High output full set cotton swab machine

    Unit Price: 0.04~0.1 USD
    Min. Order: 100000 Piece/Pieces
    Productivity: 20000
    Brand: huaxia
    Place of Origin: China
    Supply Ability: 1, 00000 Piece / Day
    Port: Shanghai

Product Description

Disposable dry cotton swabs are used as a detoxifier for skin disinfection before injection. Most hospitals use small bottles or individually packaged iodophor cotton swabs and alcohol swabs, and dry cotton swabs are often used for subcutaneous injection or intramuscular injection and local compression when measuring blood sugar. The relevant regulations of the Chinese health industry standard state that the validity period of the sterile cotton swab is 24 hours after it is opened, and it must be sealed in time after each use to maintain its airtightness.

Model No. DS-C Material Rubber Plastic
Certificate ISO Usage Lab,Hosp
Trademark JSHXRT Specification 120piece/ bag
Origin Taizhou
High output full set cotton swab machine
High output full set cotton swab machine

Product Name Disposable Sampler
Model/Type C: 100piece/ bag, 120pieces / bag
Intended Use Disposable Sampler is intended is used for collection, transportation and storage of samples(viruses, chlamydiae, mycoplasma and ureaplasma).
Indication Used for collection, storage and transportation of viruses, chlamydiae, mycoplasma and ureaplasma.
Contraindication
The product is strictly prohibited for the sampling of bacterial samples, and the preservative liquid itself contains antibiotics which inhibit the bacteria.
Test population Applicable for all population necessary for swabbing
Intended users Qualified doctors, nurses for specimen collection in a medical laboratory or hospital
Component It is usually composed of swabs.
Scope of application It is used for collection, transportation and storage of samples.
Precautions/cautions
  1. This product is for single use only. It must be strictly implemented according to the instruction for use.
  2. It should be destroyed immediately after use.
  3. It is forbidden to reuse.
  4. The disposal of its wastes should be carried out according to the relevant laws and regulations of the state on environmental protection.
  5. Products should be stored in dry, ventilated, radiant, clean rooms.
  6. The batch number of the product is at the seal of the packing, and it is valid for 2 years.
  7. Please read the instruction manual carefully and pay attention to the date of production and batch number before use.
Warning
  1. This product is a disposable product, so it is forbidden to reuse. After use, it should be treated as medical waste;
  2. Before use, please pay attention to whether the packaging and products are damaged or have other obvious defects. Please check whether the product is within the validity period. If it is beyond the validity period, please do not use it.
3. Please read the relevant instructions carefully before use, and be familiar with the instructions and operation methods of the product.
Instruction for use 1.Sterilization of the sampling tube and swab can be done before the medical institution or the user is used.
2.Annotate the relevant sample information on the sampling tube and inject an appropriate amount of sample solution.
3.According to different sampling requirements, sample swabs were sampled at the corresponding locations, holding the handle gently inserting the swab into the sampling area, gently rotating the swab 3-5 times, and then slowly removing it.
4.The sample is put into the sampling tube, and the sample swab is broken out of the sampling tube, then the tube cover is tightened, and the sample is sealed to complete the sampling.
5.The newly collected clinical specimens should be transported to the laboratory within 48 hours at 4ºC, and can not be sent to the laboratory for 48 hours. They should be kept at -70ºC or below. Specimens sent to the laboratory should be inoculated and separated as soon as possible, and can be stored at 4ºCfor 48 hours. If the inoculum is not inoculated, it should be kept at -70 ºC or below.
6.The conventional sampling methods are as follows:
A) nasal swab: gently wipe the swab head into the nasal passages of the nasal passages, and then slowly exit after stopping for a moment. Wipe the other nostrils with another swab, immerse the swab head in the sample, and discard the tail.
B) pharyngeal swabs: wipe the bilateral pharyngeal tonsils and the posterior pharyngeal wall with swabs, immerse the swab head in the sampling fluid, and discard the tail.
C) gargle: gargle with 10mL normal saline, rinse the head back, make the "Oh" sound, let the saline rotate in the pharynx, and collect the lotion with the 50mL empty sampling tube.
D) nasal lotion: the patient took his posture and his head was slightly backward, injecting 50mL normal saline into the nostril by pipette. He told the patient to simultaneously send K tone to close the pharyngeal cavity, then let the patient lower his head and let out the normal saline, collect the lotion with 50mL empty sampling tube, and repeat the process to wash the two nostrils.
E) nasopharyngeal aspirates: tracheal and bronchial secretions are often collected by this method. Mucus is extracted from the nasopharynx with a collector connected to a negative pressure pump. First, the collector head is inserted into the nasal cavity, and the negative pressure is turned on. The head of the collector is collected and slowly pushed out. Collecting mucus and washing the collector with liquid 5mL for three times.
F) autopsy specimens: autopsy tissue specimens were collected and samples were separated when necessary. Specimens were autopsy tissue.
G) samples of mycoplasma, chlamydia and Ureaplasma samples: male: use sterile cotton swabs to rotate around the urethra about
2cm for a few seconds. Female: remove the mucus from the cervical mucus and insert the 1-2cm into the cervical canal with sterile swab.
Shelf Life
2 years
Duration
single-use only
Storage condition
Store at ambient temperature and store in dry and ventilated places. Be careful of damp. Do not store with poisonous or special smell. Avoid direct contact with fire sources and inflammable and corrosive substances.
Company:Jiangsu Huaxia Ruitai Plastic Industry Co. Ltd.
Address:Modem technology industry Zone, Jiangyan District,Taizhou, City.

Company: Wellkang Ltd
Address: 16 Castle Street, Dover, CT16 1PW, England, UK









Jiangsu HXRT MD Co.,Ltd

 

Jiangsu Huaxia Ruitai Medical Equipment Co., Ltd. was established in 2013. The company is located in the Modern Science and Technology Industrial Park, Jiangyan District, Taizhou City, Jiangsu Province. It is a high-tech enterprise engaged in the research and development and production of disposable laboratory inspection consumables, cell culture, molecular biological consumables and laboratory auxiliary instruments. Mainly engaged in centrifuge tubes, flocking swabs, cell culture dishes, virus sampling tubes, single-use virus samplers, single-use virus sampling tubes, spit liquid collector, spit liquid collector, automatic extractor, and automatic nucleic acid The company occupies an area of 30,000 square meters for extractors and other products. It has standard workshops, complete production equipment, a good production environment and a group of high-quality production, technology, and management personnel, and has formed a complete quality assurance system.



The company always takes "R&D and innovation, pursuit of quality" as its corporate purpose, focusing on laboratory testing consumables, cell culture, laboratory auxiliary equipment and other fields, focusing on continuous innovation and development, improving product technology content, enriching product categories, and achieving product upgrades. Enhance the core competitiveness of enterprises.


Huaxia Ruitai regards product quality as the vitality of the company, and has established a complete set of strict internal quality control system in accordance with international quality standards to conduct batch-by-batch quality inspection from raw materials to finished products, focusing on the production of high-quality products attentively, ensuring the authenticity of experimental testing data Effective and cost-effective make products more competitive.


At the same time, Huaxia people are constantly strengthening the systematic training of employees, continuously enhancing the optimization of customer service, and truly focusing on quality and service to create more customer value. Huaxia people are willing to cooperate sincerely with people from all walks of life, and will continue to work with more industry elites in a solid and solid manner, and do their responsibilities for the health of all mankind.

Company Info
  • Company Name: Jiangsu HXRT MD Co.,Ltd
  • Representative: chen chun hua
  • Product/Service: Disposable Swab , VTM Tube , Saliva Collection Kit , Extraction Tube , Blood Collection Tube , Cryo Tube
  • Capital (Million US $): 20000000RMB
  • Year Established: 2013
  • Total Annual Sales Volume (Million US $): US$5 Million - US$10 Million
  • Export Percentage: 31% - 40%
  • Total Annual Purchase Volume (Million US $): US$5 Million - US$10 Million
  • No. of Production Lines: Above 20
  • No. of R&D Staff: 5 -10 People
  • No. of QC Staff: 5 -10 People
  • OEM Services Provided: yes
  • Factory Size (Sq.meters): 10,000-30,000 square meters
  • Factory Location: No.66 Xingyuan Road, the Modern Science and Technology Industrial Area,Jiangyan District, Taizhou City,225300, Jiangsu, China
  • Contact Person: Ms. Vivian
  • Tel: +86-0523-88310598